ULTRASENSITIVE AIR PRESSURE SENSOR Model : FKS-111 |
|
 Features

This sensor can detect very small pressure change of air and gas which are hardly detected by conventional sensors. Large pressure change, 100kPa can be detected by this sensor as well. |
Comparing with conventional diaphragm type sensors, this is reasonably priced and has high sensitivity, and its sensing element is of ceramic which has good advantage against damage caused by excessive pressure. |
This sensor is with built-in FET to convert impedance and so, the signal is available with output voltage. |
|
Applications |
 |
| |
Feature of this ultra high sensitivity air-pressure sensor can be used as a sensor to convertvery low pressure (1Pa)
This sensor can be used as a sensor to detect opening/closing doors at well sealed rooms.
This sensor can be used for sensitive pressure change sensors.
Besides above, this sensor can be used for appliances and equipments for home-automation, safe & security, industrial & other air-switches. |
Representative Characteristic |
 |
 |
Standard Specification |
 |
|
Direction of output voltage |
 |
In the standard specs.,output voltage is at (+) when increasing pressure. Model : FKS-111
On request, output voltage can be arranged at (+) when decreasing pressure. Model : FKS-111M
*When a small pressure change is detected, the use of RESIN-CAP of the option is recommended.
*Learning Module (Model:FKS-TM01) to understand the function of the air pressure sensor is prepared, and consult, please.
Click here.
* Signal detection at the time of abnormalities is performed from Air Pressure sensor for the purpose of Security (Car & Home), and it is as an unusual detection signal. It outputs outside. Please consult also about a "Ultrasensitive Air Pressure Digital Module".
■The presentation which inserted the animation in part. Click here. 
Note : These specifications are subject to change without notice.
|
|
|